久久精品一区二区日韩av-精品美女高潮久久久-熟妇丰满多毛的大阴户-国产精品视频不卡一区二区

Product Details
  • 產(chǎn)品名稱:HSE-HA Pressure Monitor & Limiter for Small Animals

  • 產(chǎn)品型號(hào):
  • 產(chǎn)品廠商:Ventilators
  • 產(chǎn)品價(jià)格:0
  • 折扣價(jià)格:0
  • 產(chǎn)品文檔:
你添加了1件商品 查看購(gòu)物車
簡(jiǎn)單介紹:
The HSE-HA Pressure Monitor and Limiter is placed between the ventilator and animal. Excessive pressures are released by an overpressure valve, protecting the ventilator and animal. It is an ideal control tool for controlling pressure on mechanical ventilators, such as MicoVent, MiniVent, MidiVent, Model 687 and Model 683.
詳情介紹:

The HSE-HA Pressure Monitor and Limiter is placed between the ventilator and animal. Excessive pressures are released by an overpressure valve, protecting the ventilator and animal. It is an ideal control tool for controlling pressure on mechanical ventilators, such as MicoVent, MiniVent, MidiVent, Model 687 and Model 683.

? Set peak pressure range anywhere between 10-50 cmH2O
? Reduces animal mortality and lung damage
? Continuous pressure measurement during ventilation
? Pressure is released by an overpressure valve
? Analog pressure signal output to record with DAQ software and TTL output 
    of valve status
? Audible alarm

Item# Description U.S. List Price Quantity
73-4329 Respiratory Pressure Monitor & Limiter for Mouse
73-4330 Respiratory Pressure Monitor & Limiter for Rat
73-4336 Ball Holder to MicroVent, MiniVent and MidiVent
73-4337 Bar with Magnetic Ball - for Positioning and Mounting HSE-HA Pressure Monitor & Limiter Actuator Head
73-0566 Plexiglass Block Clamp for mounting 73-0562 Bar onto Lab Stand
73-0500 Lab Stand with Triangular Base Plate, 30 cm Rod Length (one block clamp included)
The HSE-HA Pressure Monitor and Limiter is placed between the ventilator and animal. Excessive pressures are released by an overpressure valve, protecting the ventilator and animal. It is an ideal control tool for controlling pressure on mechanical ventilators, such as MicoVent, MiniVent, MidiVent, Model 687 and Model 683.

? Set peak pressure range anywhere between 10-50 cmH2O
? Reduces animal mortality and lung damage
? Continuous pressure measurement during ventilation
? Pressure is released by an overpressure valve
? Analog pressure signal output to record with DAQ software and TTL output of valve status
? Audible alarm

73-4329 includes: Actuator Head Mouse type 384/I and Respiratory Pressure Monitor & Limiter type 870/I and bar with magnet holder, 100-240 VAC, 50/60 Hz

73-4330 includes: Actuator Head Rat 384/2 and Respiratory Pressure Monitor & Limiter type 870/I and bar with magnetic holder, 100-240 VAC, 50/60 Hz.


姓名:
電話:
您的需求:
 

京公網(wǎng)安備 11010702001780號(hào)